Solenoid Valves - Cartridge Style
SVV0.S08
SAE Cartridge - 350 bar
NO Single Lock Pilot Operated
Poppet type
Description
A solenoid valve operated, 2-way 2-positions, normally open, piloted poppet type, screw-in cartridge valve. Typically used as a blocking or load holding device for high pressure circuits. When the coil is de-energized, the SVV0.S08 allows flow from 1 to 2, while flow from 2 to 1 is severely restricted. When the coil is energized the valve closes, blocking flow from 1 to 2. In this mode, flow from 2 to 1 is allowed once the pressure overcomes the force of the solenoid. The rigid design using a 1-piece body contributes to minimize the effect of eccentricities in cavity and provides great reliability. Low pressure drop thanks to optimized flow path.
Technical Features
All external surfaces are zinc plated and corrosion-proof. All valve parts are made of high strength steel. Poppet is hardened and ground to ensure minimal wear and extended service life. Coil seals protect the solenoid system. Manual override option. Industry SAE common cavity. It replaces the previous SVU0.S08.
Technical data
Maximum operating pressure
350 bar
Maximum flow
40 l/min
Switch ON Time
100 ms
Switch OFF Time
50 ms
Maximum internal leakage
0,25 cm3/min @ 350 bar
External component treatment
Zn/Fe - standard (96h)Zn/Ni (720h) - Upon customer request
O-ring temperature range
-30 ° C to 110 ° C (standard sealing NBR - BUNA - N)-35 ° C to 140 ° C - HNBR - Upon customer request-23 ° C to 225 ° C - FKM - Upon customer request
Oil temperature range
-30 ° C to 110 ° C
Fluids
Mineral - based or synthetics with lubricating properties
Viscosities
7,4 to 420 cSt
Minimum pull-in voltage
85% of nominal
Filtration
20 / 18 / 15 ISO 4406 (maximum filtration admitted)
Orientation
No restrictions
Installation torque
40 - 45 Nm  Hex 24
Oil testing condition
ISO VG 46 cSt
Seal Kit
SK.030 and SK.027 (coil)
Coil
Weight
0,125 Kg
Cross Section
Cavity Details

Performance details